ETCR8200 Storage Battery Tester - etcr

ETCR8200 Storage Battery Tester

Main Function

1. It can judge whether the battery is well or not by testing the conductance of the battery, quickly find out the battery fault and timely maintain the battery, so as to give full play to the battery's performance and extend the battery's service life.

2. Battery Capacity : 30~300AH

3. Conductance range : 300S~2200S

4.  Store Data : 100 groups






  ETCR8200 Storage Battery Tester  can judge whether the battery is well or not by testing the conductance of the battery, quickly find out the battery fault and timely maintain the battery, so as to give full play to the battery's performance and extend the battery's service life.  Used for new battery acceptance and single battery process and performance consistency testing; Match battery team which the battery conductance value error within ±10% can maximize the efficiency of the battery and greatly extend its service life. Through the battery conductance testing, the disabled batteries are found via the transverse comparison of conductance value, and the faulty batteries are quickly found to improve the maintenance and guarantee efficiency. Through daily storage battery conductance/capacity testing, organize discharge capacity test in time to verify actual capacity. Through the battery conductance testing screening and warning, targeted implementation of battery capacity test, improve the battery capacity test and operational performance early warning efficiency.

Technical Specification

Applicable Battery Type

 12V valve-controlled type sealed lead-acid battery

Battery Capacity

 30~300AH

Conductance range

 300S~2200S

Conductance Accuracy

 ±3%

Voltage Accuracy

 5mV

Calibration Function

 Automatic Calibrate

Display

 LCD green backlight

Store Data

 100 groups

Host Weight

 750g

Host Dimension

 180x95x32mm

Working Temperature

 -10℃~40℃;below 80%rh

Stored Temperature

 -10℃~60℃;below70%rh

Accessories

 Host: 1PCS; Alligator clip test line: 1PCS; Probe test line: 1PCS; USB communication cable: 1PCS; 

Comparison sheet between the measured conductance value and reference value

The Measured conductance value & reference value

Battery State

 Battery maintenance methods suggestion

>80%

The battery is well, continue to use

 Check the appearance of the battery for physical damage or not

60~80%

Batteries are beginning to deteriorate and need attention

 According to the international standard IEEE (1118-1996) stipulation on page 15: significant change in conductance value (a drop of more than 20%) means a change in battery performance.Adopt maintenance methods:

1. Increase the battery test frequency, test once a month.

2.Replace the low conductance batteries, and maintain battery pack consistency

3. Use standard discharge (3 h rate or 10 h rate)  to verify the battery capacity

<60%

The battery is seriously deteriorated. It is recommended to replace the battery.

 The battery has been seriously degraded, and in the unstable period (or called diving period), need to immediately scrapping and replacement.